КВБбШв (NYBY)
General information
Control cables of these brands are used for stationary laying in electric and alternate current devices with a nominal voltage of 660 V or in direct current electric distribution devices with a nominal voltage up to 1000 V, in closed areas, channels and tunnels, aggressive climatic conditions and in places that are not exposed to external mechanical influence, and also for the purpose of protection from the external electromagnetic field.
КВБбШв (NYBY) / КВБбШвнг (NYBY-fl) / КВБбШвнг – LS (NYBY-LS) / AКВБбШв (NAYBY) / AКВБбШвнг (NAYBY-fl) / AКВБбШвнг–LS, (NAYBY-LS)
Control cables of these brands are used for stationary laying in electric and alternate current devices with a nominal voltage of 660 V or in direct current electric distribution devices with a nominal voltage up to 1000 V, in closed areas, channels and tunnels, aggressive climatic conditions and in places that are not exposed to external mechanical influence, and also for the purpose of protection from the external electromagnetic field.
The cores forming the cable get twisted in layers. Two cores in each layer should differ in color between themselves and other cores or must be numbered.
Structural design:
- The power core made of copper and aluminum wire
- PVC insulation or flame retardant PVC with low smoke and gas evolution
- Belt insulation from PVC emission
- Armor made of two galvanized steel tapes
- PVC jacket or flame retardant PVC with low smoke and gas emission
Technical characteristics of the cable:
Wire type | Conductor cross-sectional area, mm2 | Estimated weight of the wire, kg/km | Maximum electrical resistance of the power core at 20 °С, Оhm/km, not more than |
КВБбШв (NYBY) | 4 x 1.0 5 x 1.0 7 x 1.0 10 x 1.0 14 x 1.0 19 x 1.0 27 x 1.0 37 x 1.0 | 270 304 346 445 524 618 793 379 | 18.10 |
4 x 1.5 5 x 1.5 7 x 1.5 10 x 1.5 14 x 1.5 19 x 1.5 27 x 1.5 37 x 1.5 | 303 344 395 514 605 733 951 1210 | 12.10 | |
4 x 2.5 5 x 2.5 7 x 2.5 10 x 2.5 14 x 2.5 19 x 2.5 27 x 2.5 37 x 2.5 | 364 418 491 648 781 963 1292 1634 | 7.41 | |
4 x 4.0 5 x 4.0 7 x 4.0 10 x 4.0 | 467 545 651 865 | 4.61 | |
4 x 6.0 7 x 6.0 10 x 6.0 | 570 808 1099 | 3.08 |
Technical specifications:
- Nominal operating voltage: 660 V
- Conductor cross-section. mm2: 0.75, 1.0, 1.5, 2.5, 4.0, 6.0, 10.0
- Number of cores: 2 to 61
- Relative humidity of the atmosphere: 98 %
- Operating temperature of the cable: -50 °C / + 50 °C
- Service life: under the ground and on the bridges - 15 years, in closed areas, canals and tunnels - 25 years