General information
A-DF(ZN)2Y / A-DF(BN)2Y (ОККм/ОККмС) type fiber optic cable with dielectric structure, single-layer coated, with aramid or fiber glass yarns for suspension on power line pylons
CABLE CONSTRUCTION DESIGN
Optical fibers are freely placed inside polymer tubes and interstice is filled with a hydrophobic gel. Polymer tubes are SZ stranded around a central-strength member. Interstice between stranded tubes is filled with hydrophobic gel and covered with PET tape. Reinforcing aramid yarns or glass fiber yarns and high-density polyethylene outer jacket are imposed on the cable core.
- Central member
- Polymer tube
- Optical fiber
- Hydrophobic gel (intramodular)
- Insulating cord
- Hydrophobic gel (intermodular)
- PET tape
STRUCTUAL DESIGN OF CABLE
Optical fibers are freely placed inside polymer tubes and interstice is filled with a hydrophobic gel. Polymer tubes are SZ stranded around a central-strength member. Interstice between stranded tubes is filled with hydrophobic gel and covered with PET tape. Reinforcing aramid yarns or glass fiber yarns and high-density polyethylene outer jacket are imposed on the cable core.
- Central member
- PBT tube
- Optical fiber
- Hydrophobic gel (intramodular)
- Insulating cord
- Hydrophobic gel (intermodular)
- PET tape
- Aramid yarns (ZN) or fibers glass yarns (BN)
- Outer protective jacket
COLOR IDENTIFICATION OF FIBERS AND TUBES (IEC 60304)
1-12
1
2
3
4
5
6
7
8
9
10
11
12
Fiber
red
green
dark blue
yellow
white
grey
brown
purple
blue
black
orange
pink
Tube
red
green
dark blue
yellow
white
grey
brown
purple
blue
black
orange
pink
On customer’s request, the color identification of fibers and tubes (and color assembly sequence of tubes) can be changed.
The number of optical fibers
2-24
26-48
50-72
74-96
98-144
The number of tubes(max.)
6
6
6
8
12
Number of fibers in a tube (max)
4
8
12
12
12
Temperature range during operation
-40 °C.....+60 ºC
Temperature range during installation
-10 °C.....+50 ºC
Temperature range during transportation and storage
-50 ºC......+50 ºC
Minimum bend radius
20xD
Tensile strength (IEC 60794-1-2)
1 ÷ 3.5 kN
Crush strength (IEC 60794-1-2)
3.0 kN/100 mm (min)
- Aramid yarns (ZN) or fibers glass yarns (BN)
- Outer protective jacket
COLOR IDENTIFICATION OF FIBERS AND TUBES (IEC 60304)
1-12 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
Fiber | red | green | dark blue | yellow | white | grey | brown | purple | blue | black | orange | pink |
Module | red | green | dark blue | yellow | white | grey | brown | purple | blue | black | orange | pink |
On customer’s request, the color identification of fibers and tubes (and color assembly sequence of tubes) can be changed.
The number of optical fibers | 2-24 | 26-48 | 50-72 | 74-96 | 98-144 |
The number of tubes(max.) | 6 | 6 | 6 | 8 | 12 |
Number of fibers in a tube (max) | 4 | 8 | 12 | 12 | 12 |
|