ОКЛТ-Т
General information
A-D(ZN)2Y(SR)T2Y / A-D(BN)2Y(SR)T2Y (ОКЛТ-Т) type fiber optic cable armored with laminated corrugated steel tape armor, double-sheathed, with (eight-stranded) suspension rope for suspension on power line pylons
Structural design of cable
The bearing member is placed in parallel to the twisted conductor. The bearing member can consist of a steel rope or a dielectric-based strength member (fiberglass rod). Optical fibers are freely placed inside the tube and interstice is filled with a hydrophobic gel. In addition to aramid yarns or fiber glass yarns, polyethylene inner jacket is imposed on the central tube. Internally jacketed cable core is sheathed with laminated corrugated steel tape armor, and the bearing member is sheathed with a high-density polyethylene outer jacket.
- Steel rope (T)/ steel wire (Ts)
- Glass rod (Td)
- Optical fiber
- Hydrophobic gel
- Inner jacket
- PBT tube
- Aramid yarns (ZN) or fiberglass yarns (BN)
- Corrugated steel tape armor
- Outer jacket
Color Identification of fibers and tubes (IEC 60304)
1-12 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
Fiber | red | green | dark blue | yellow | white | grey | brown | purple | blue | black | orange | pink |
On customer’s request, the color identification of fibers and tubes can be changed.
Number of fibers | 2-12 |
Number of tubes | 1 |
Temperature range during operation | -60 °C.....+70 ºC |
Temperature range during installation | -10 °C.....+50 ºC |
Temperature range during transportation and storage | -60 ºC......+70 ºC |
Minimum bend radius | 20xD |
Tensile strength (IEC 60794-1-2 E1) | 3.5 ÷ 9 kN |
Crush strength (IEC 60794-1-2 E3) | 2.0 kN/100 mm (min) |
Temperature range of operation | -60°C.....+70ºC |
Temperature range of installation | -10°C.....+50ºC |
Temperature range of transportation and storage | -60ºC......+70ºC |
Minimum bend radius | 20xD |
Tensile strength (IEC 60794-1-2 E1) | 3.5 ÷ 9 kN |
Crush strength (IEC 60794-1-2 E3) | 2.0 kN/100 mm (min) |