ОКЛТ-Т

General information

A-D(ZN)2Y(SR)T2Y / A-D(BN)2Y(SR)T2Y (ОКЛТ-Т) type fiber optic cable armored with laminated corrugated steel tape armor, double-sheathed, with (eight-stranded) suspension rope for suspension on power line pylons

Structural design of cable

The bearing member is placed in parallel to the twisted conductor. The bearing member can consist of a steel rope or a dielectric-based strength member (fiberglass rod). Optical fibers are freely placed inside the tube and interstice is filled with a hydrophobic gel. In addition to aramid yarns or fiber glass yarns, polyethylene inner jacket is imposed on the central tube. Internally jacketed cable core is sheathed with laminated corrugated steel tape armor, and the bearing member is sheathed with a high-density polyethylene outer jacket.

  1. Steel rope (T)/ steel wire (Ts)
  2. Glass rod (Td)
  3. Optical fiber
  4. Hydrophobic gel
  5. Inner jacket
  6. PBT tube
  7. Aramid yarns (ZN) or fiberglass yarns (BN)
  8. Corrugated steel tape armor
  9. Outer jacket

Color Identification of fibers and tubes (IEC 60304)

1-12

1

2

3

4

5

6

7

8

9

10

11

12

Fiber

red

green

dark blue

yellow

white

grey

brown

purple

blue

black

orange

pink

On customer’s request, the color identification of fibers and tubes can be changed.

Number of fibers

2-12

Number of tubes

1

 

Temperature range during operation

-60 °C.....+70 ºC

Temperature range during installation

-10 °C.....+50 ºC

Temperature range during transportation and storage

-60 ºC......+70 ºC

Minimum bend radius

20xD

Tensile strength (IEC 60794-1-2 E1)

3.5 ÷ 9 kN

Crush strength (IEC 60794-1-2 E3)

2.0 kN/100 mm (min)

 

Temperature range of operation-60°C.....+70ºC
Temperature range of installation-10°C.....+50ºC
Temperature range of transportation and storage-60ºC......+70ºC
Minimum bend radius20xD
Tensile strength (IEC 60794-1-2 E1)3.5 ÷ 9 kN