ОКТ-Т
General information
A-DT2Y (ОКТ-Т) type fiber optic cable with a central tube on which a single-layer (eight-stranded) suspension rope is put for suspension on power line pylons
STRUCTURAL DESIGN OF CABLE
The bearing member is placed in parallel to the twisted conductor. The bearing member can consist of a steel rope or a dielectric-based strength member (fiberglass rod). The cable core consists of the central tube. Optical fibers are freely placed inside the tube and interstice is filled with a hydrophobic gel. The high-dense outer jacket is imposed on the cable core (tube) and parallel bearing
- Steel rope (T)/ steel wire (Ts)
- Glass rod (Td)
- PBT tube
- Optical fiber
- Hydrophobic gel
- Outer protective jacket
COLOR IDENTIFICATION OF FIBERS AND TUBES (IEC 60304)
1-12 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
Fiber | red | green | dark blue | yellow | white | grey | brown | purple | blue | black | orange | pink |
Tube | red | green | dark blue | yellow | white | grey | brown | purple | blue | black | orange | pink |
On customer’s request, the color identification of fibers and tubes can be changed.
The number of optical fibers | 2-12 | ||||
Number of tubes (max) | 1 | ||||
Number of fibers in a tube (max) | 12 |
Temperature range during operation | -40 °C.....+60 ºC |
Temperature range during installation | -10 °C.....+50 ºC |
Temperature range during transportation and storage | -50 ºC......+50 ºC |
Minimum bending radius | 20xD |
Tensile strength (IEC 60794-1-2) | 1 ÷ 3.5 kN |
Crush strength (IEC 60794-1-2) | 3.0 kN/100 mm (min) |
Temperature range of operation | -40°C.....+60ºC |
Temperature range of installation | -10°C.....+50ºC |
Temperature range of transportation and storage | -50ºC......+50ºC |
Minimum bending radius | 20xD |
Tensile strength (IEC 60794-1-2) | 1 ÷ 3.5 kN |
Crush strength (IEC 60794-1-2) | 3.0 kN/100 mm (min) |